Recording a Manual Fusion with the DataLogger®

Documenting operator and machine information, material details, standards used, and GPS locations of a manual fusion is all possible with the DataLogger. 1. Choose your fusion machine during the job setup process. The software will adapt the recording process based on your machine selection. 2. Choose Fusion Type and Standard used. 3. Capture setup photos, document jobsite conditions, pipe details and heater temperature. 3. Review details. 4. Begin fusion. The DataLogger will record all important …

Read More

Understanding Exception Reporting in The Vault™

The exception reporting feature gives users a visual tool to quickly analyze and review their joint reports. By reviewing heat soak time and pressure, open/close times, fuse/cool times and pressures, and pressure transducer calibration, the Vault automatically flags joints that fall outside of acceptable standards for further analysis and follow-up. OVERVIEW On each Job Record page, a Joint Analysis dashboard displays joints that are acceptable, rejected, or are in need of Review. Fusion joints that …

Read More